IntroductionExperimental observation of transverse MO effectProperties of transverse MO effectOrigin of transverse MO effectTransverse EllipticityTwo contributions to transverse MO effectMagnetization-dependent optical lossCalculations of transverse MO effect in the case of multilayer structureOptical excitation of spin-polarized electrons utilizing transverse MOPlasmonsGiant Enhancement of Transverse MO effectHistory and Future |
Measurement of non-linear refractive index and non-linear optical absorption
High-precision high-sensitivity measurementsThe measurement setup with a 2x2 optical allows to measure a very small non-linear change of optical absorption and refractive index with a very high precision.
|
Fig. 1. Setup for measurements of non-linear change of optical absorption |
||||||
|
||||||
At left case, light of a lower intensity passes through the sample. At left case, light of a lower intensity passes through the sample. It is critically important that in both cases the intensity of emitted light at the sources is the same and the the intensity of detected light at the detector is nearly the same. There is a small difference of the detected signal due to the non-linear absorption of the sample. Click on image to enlarge it |
Figure 1 shows the proposed setup for measurements of non-linear absorption. Figures 1 (a) and (b) show two switch states of the switcher. The attenuator is inserted between the sample and the fiber switcher. For one switching state of the switcher, light is passing the absorber at first and next the sample (Fig.1 (a)). For another switching state of the switcher, it is opposite. Light is passing through the sample at first and next through the absorber (Fig.1 (b)). Therefore, light of different intensity is passing through the sample for the different switching states. In contrast, at detector the intensity of light is nearly-same for both switching states. It is because for both switching states, light is passing through all the same elements on the path from the source to the detector. In the case when the absorption of the sample does not depend on the light intensity, the intensity of light at the detector is exactly the same for both switching states. In the case when the absorption of the sample is dependent on the light intensity, there is a tiny difference in intensity of light at the detector. This difference can be measured with a high precision using the lock-in technique and the non-linear absorption of the sample can be evaluated. In the case when an tunable attenuator is used, the dependence of the non-linear absorption on light intensity can be measured.
Setup for measurements of non-linear change of optical absorption using lock-in technique |
The electrical pulses from the pulse generator switch the 2x2 optical switch. It change intensity of light, which passes through the sample. As result, the detected signal is modulated with amplitude, which is proportional to the non-linear change of the absorption in the sample. Click on image to enlarge it |
This method was
I will try to answer your questions as soon as possible